Thermal Acoustic Insulation Flame Propagation Apparatus

Compliance

14 CFR 25.853 Part VI, Boeing BSS 7365, Airbus AITM 2.0053


Thermal / Acoustic Insulation Flame Propagation Apparatus, in accordance with FAR Part 25 Appendix F Part VI, is designed to evaluate the flammability and flame propagation characteristics of thermal or acoustic insulation material used in aircraft cabin when exposed to an electric radiant heat source and a defined flame source.

The Thermal / Acoustic Insulation Flame Propagation Apparatus also comforts to following standards:

Boeing BSS 7365 Insulation (Flame Propagation)

Airbus AITM 2.0053 Insulation (Flame Propagation)

The Thermal / Acoustic Insulation Flame Propagation Apparatus consists of

  • The radiant panel test chamber is stainless steel made and with interior 0.5-inch refractory board. Consists of a glass viewing window, internal chimney, and sliding tables.

  • The radiant heat source is a 400VAC 3 phase electric heating plate with PID temperature control and a temperature control accuracy of 0.1 degrees.

  • The radiant heat source is mounted in a frame with six 76mm wide radiant strips, the long side of which is perpendicular to the electric heating plate capable of withstanding an operating temperature of not less than 704 degrees.

  • The radiation plate is placed in the test chamber at an angle of 30 degrees to the horizontal plane of the specimen.

  • A pneumatic sliding table is provided to enable the user to achieve automatic control of the entry and exit of the specimen.

  • The burner is an axisymmetric, 0.15mm aperture propane-air burner with venturi pre-mix device.

  • A movable burner (pneumatic drive) that allows the flame to be horizontal and at least 51 mm above the specimen plane.

  • A thermocouple that can be inserted at the back of the case, 279mm from the back wall of the case, 292mm from the right side of the case wall and located 51mm below the radiation plate, with an accuracy of 2 degrees.

  • Water-cooled heat flux meter with a measurement range of 0 to 50 KW/m2, equipped with a self-circulating water cooling system.

  • The calibration holding frame has three 25.4mm diameter jacks through the support plate, the centre of the first jack being 191±3mm from the surface of the thermal radiation plate and the centre of the two adjacent jacks being 51mm apart.

  • Provides with two specimen holders, 2 sample holders, one standard type, and one short type for hook and loop testing.

  • Equipped with data acquisition system, window software.